PH Sensor
WPH1008
Features
- Compact structure and easy installation
- Isolated power supply design, data stability, strong anti-interference ability
- Automatically detect whether the temperature probe is disconnected or faulty
- Support USA/NIST/custom pH calibration solution, and user-defined ORP standard solution
- Communication: RS485 interface*1 (Modbus RTU protocol)
The 1008 pH digital sensor designed for the aquaculture industry is equipped with numbers interface (RS485*1), can be used for measuring aqueous solution system within the range change in pH/ORP.The 1008 pH sensor is applied in different fields: Aquaculture, water quality testing, information data collection, Internet of Things water quality testing. The pH digital sensor, which our business created for the aquaculture sector.
01
Industrial pH Monitoring: pH and pH Sensor Basics
1008 ph industrial planar PH sensor is made of ring-type polytetrafluoro-reference liquid interface, solid electrolyte and special glass sensitive film, so that the reaction speed and anti-pollution ability of the sensor are enhanced and its performance reaches the level of similar sensors in the world.
The principleof pH/ORPsensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which ismade up of 2half-cells, of which one is called ameasuring cell whose potential is related to specific ionic activity;the otheris a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument. The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value.The pH sensor wire is not waterproof, so it shall be avoided to be contact with water as far as possible. A wide selection of sensor body styles and process fings in a variety of corrosion resistant materials allow direct replacement.
02
Application of pH Sensor
Industrial wastewater engineering. Process measurements, electroplating plants, paper industry, drinks industry. Wastewater containing oil. Suspensions, varnishes, media containing solid particles. Two-chamber system for when electrode poisons are present. Media containing fluorides (hydrofluoric acid) up to 1000 mg/l HF. Isolated power supply design, data stability, strong anti-interference ability
03
pH Sensor
The sensor with a standard RS485 MODBUS-RTU protocol interface, which can be connected with the host computer conducts remote communicaon Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & HighTemp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulaons.
pH Calibration
Enter the PH calibration screen, the first PH electrode intothe4.00PH standard solution, standing for a moment, to be stable after the show, press the ENT, then the PH electrode into the 6.86PH standard solution Set the PH electrode into the 9.18PH standard solution, put it aside for a moment, after the test is stable, press ENT, the display shows the success of the calibration, the whole process of PH calibration complete
Technical Specification
Product
Digital pH sensor
Model
WPH1008
Measurement range
0.00-14.00pH; ±1000.0mV
Resolution
0.01 pH, 0.1 mV
Temperature
0-60℃
Accuracy
0.02pH, 0.5℃, 0.2mV
Output
RS485
Communication
Modbus-RTU
Power supply
12VDC
Sensors
Features
Compact structure and easy installation
Isolated power supply design, data
stability, strong anti-interference ability
automatic/manual temperature
compensation
Automatically detect whether the
temperature probe is disconnected or
faulty, then switch to manual
temperature compensation
Support USA/NIST/custom pH calibration
solution, and user-defined ORP standard
solution
Communication: RS485 interface*1
(Modbus RTU protocol)
The principleof pH/ORPsensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which ismade up of 2half-cells, of which one is called ameasuring cell whose potential is related to specific ionic activity; the other is a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument.The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value. WKP100 is a digital sensor with RS485 designed by our company for the aquiculture industry, which can be used to measure the change of pH/ORP value in an aqueous solution system within the range. The sensor with a standard RS485 MODBUS-RTU protocol interface, which can be connected with the host computer conducts remote communication Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations.
Applications
Heating and Cooling Reactors
Disinfecting and
Sterilizing
Waste Heat Recovery Boilers
Dyeing WasteWater
Exhaust Gas Treatment
Fertigation System
Accessories
Documents
Wellkonix global commitment to the Chemical Industry
Wellkonix is the world leader in automation solutions to the chemical industry. As a global player, we have strong local support in any region that you run your business
Solutions
automation
Project execution
Providing solutions of every kind, at all times in chemical industries
WellKonix engineers were all very affected person and cooperative during the early engineering and start-up phases. We labored as one team thru to the completion of this plant project