Wellkonix WPH1006
Plastic pH electrode
Features
- Industrial wastewater engineering
- Process measurements, electroplating plants, paper industry, drinks industry
- Wastewater containing oil
- Suspensions, varnishes, media containing solid particles
- Two-chamber system for when electrode poisons are present
- Media containing fluorides (hydrofluoric acid) up to 1000 mg/l HF
In the disciplines of wastewater treatment, mining and smelting, papermaking, paper pulp, textiles, petrochemical industry, semiconductor electronics process, and downstream biotechnology engineering.The reference electrode and the glass or metal electrode are united in one shaft because they are intended to function as combined electrodes. Depending on the kind, a temperature probe may also be integrated.
01
Industrial pH Monitoring: pH and pH Sensor Basics
The sensor 1006 can be directly used with a variety of domestic or imported pH meter.
The principle of pH/ORP sensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which is made up of 2half-cells, of which one is called a measuring cell whose potential is related to specific ionic activity; the other is a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument. The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value. The pH sensor wire is not waterproof, so it shall be avoided to be contact with water as far as possible. Adopt international advanced solid dielectric and large area PTFE liquid junction, no clogging, easy maintenance. Long distance reference diffusion path, extends electrode life greatly in harsh environments. Side or vertically installation to the reaction tank or pipe. Installation: Submersible installation, pipe installation, thread Installation, flange installation.
02
Application of pH Sensor
Industrial wastewater engineering. Process measurements, electroplating plants, paper industry, drinks industry. Wastewater containing oil. Suspensions, varnishes, media containing solid particles. Two-chamber system for when electrode poisons are present. Media containing fluorides (hydrofluoric acid) up to 1000 mg/l HF. Isolated power supply design, data stability, strong anti-interference ability
03
Uses of pH Sensor
Adopt a big area PTFE liquid junction with easy maintenance and an advanced solid dielectric from across the world. Long-range reference diffusion route significantly increases electrode life in challenging conditions. Because the electrode is constructed from high-quality low-noise wire, the signal output may be produced for up to 40 meters without interference. It also has excellent precision, quick reaction times, and strong repeatability.
pH Calibration
Enter the PH calibration screen, the first PH electrode intothe4.00PH standard solution, standing for a moment, to be stable after the show, press the ENT, then the PH electrode into the 6.86PH standard solution Set the PH electrode into the 9.18PH standard solution, put it aside for a moment, after the test is stable, press ENT, the display shows the success of the calibration, the whole process of PH calibration complete
Technical Specification
Product
Plastic pH sensor
Model
WPH1006
Pressure resistance
0.4MPa
Measurement range
2~12pH
Temperature
0~80℃
Application range
Environmental protection, watertreatment, breeding, municipal
Thread Connection
3/4NPT
Installation
Submersible installation, pipe installation, thread Installation, flange installation
Wire
5m (customizable)
sensor
Φ25*165mm
Temperature compensation
NTC10K/PT100/PT1000
Sensors
Features
Compact structure and easy installation
Isolated power supply design, data
stability, strong anti-interference ability
automatic/manual temperature
compensation
Automatically detect whether the
temperature probe is disconnected or
faulty, then switch to manual
temperature compensation
Support USA/NIST/custom pH calibration
solution, and user-defined ORP standard
solution
Communication: RS485 interface*1
(Modbus RTU protocol)
The principleof pH/ORPsensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which ismade up of 2half-cells, of which one is called ameasuring cell whose potential is related to specific ionic activity; the other is a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument.The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value. WKP100 is a digital sensor with RS485 designed by our company for the aquiculture industry, which can be used to measure the change of pH/ORP value in an aqueous solution system within the range. The sensor with a standard RS485 MODBUS-RTU protocol interface, which can be connected with the host computer conducts remote communication Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations.
Applications
Heating and Cooling Reactors
Disinfecting and
Sterilizing
Waste Heat Recovery Boilers
Dyeing WasteWater
Exhaust Gas Treatment
Fertigation System
Accessories
Documents
Wellkonix global commitment to the Chemical Industry
Wellkonix is the world leader in automation solutions to the chemical industry. As a global player, we have strong local support in any region that you run your business
Solutions
automation
Project execution
Providing solutions of every kind, at all times in chemical industries
WellKonix engineers were all very affected person and cooperative during the early engineering and start-up phases. We labored as one team thru to the completion of this plant project