Features

WXP6300 industrial pH meter is an online pH analyzer which applied in chemical industry metallurgy, environment protection, food, agriculture and so on. With 4-20mA analog signal, RS-485 digital signal and relay output. Can be used for industrial processes and water treatment processes pH control, and support remote data transmission, etc.

01

ORP Measurement Basics For The Process Industry

The ability of a medium to oxidise or reduce another medium is measured by its “oxidaon-reducon potenal,” or ORP. When an oxidizer takes an electron from another molecule, it is said to be oxidising, and when a reducer gives an electron to another molecule, it is said to be reducing. A single mV value, which can be posive or negave, can be monitored by an ORP sensor to idenfy whether oxidaon or reducon is taking place. The mV value is posive when a medium is oxidising. The mV reading will be negave when it is displaying reducon. Addionally, an ORP measurement known as “Redox” is frequently used. Reducon and oxidaon are combined to form the word redox. Oxidation-reduction potential (ORP) measures the ability of a lake or river to cleanse itself or break down waste products, such as contaminants and dead plants and animals. When the ORP value is high, there is lots of oxygen present in the water. This means that bacteria that decompose dead tissue and contaminants can work more efficiently. In general, the higher the ORP value, the healthier the lake or river is. However, even in healthy lakes and rivers, there is less oxygen (and therefore lower ORP values) as you get closer to the bottom sediments (mud; see the picture below of a lake bottom). This is because there are many bacteria working hard.

02

Application of pH / ORP Transmitter

Microbiological technology, medicines, food and drink, sugar production, chlor-alkali, mining and smelting, papermaking, paper pulp, textiles, petrochemical industry, semiconductor electronic industry, and domains like sewage treatment are among the many chemical processes that use it.Wet wells, oil tanks, sump pumps, reservoirs, electroplating facilities, paper industries, wastewater, and drinking water

03

Uses of pH / ORP Transmitter

Adopt a big area PTFE liquid junction with easy maintenance and an advanced solid dielectric from across the world. Long-range reference diffusion route significantly increases electrode life in challenging conditions. Because the electrode is constructed from high-quality low-noise wire, the signal output may be produced for up to 40 meters without interference. It also has excellent precision, quick reaction times, and strong repeatability.

01

ORP Measurement Basics For The Process Industry

The ability of a medium to oxidise or reduce another medium is measured by its “oxidaon-reducon potenal,” or ORP. When an oxidizer takes an electron from another molecule, it is said to be oxidising, and when a reducer gives an electron to another molecule, it is said to be reducing. A single mV value, which can be posive or negave, can be monitored by an ORP sensor to idenfy whether oxidaon or reducon is taking place. The mV value is posive when a medium is oxidising. The mV reading will be negave when it is displaying reducon. Addionally, an ORP measurement known as “Redox” is frequently used. Reducon and oxidaon are combined to form the word redox. Oxidation-reduction potential (ORP) measures the ability of a lake or river to cleanse itself or break down waste products, such as contaminants and dead plants and animals. When the ORP value is high, there is lots of oxygen present in the water. This means that bacteria that decompose dead tissue and contaminants can work more efficiently. In general, the higher the ORP value, the healthier the lake or river.

02

Application of pH / ORP Transmitter

Microbiological technology, medicines, food and drink, sugar production, chlor-alkali, mining and smelting, papermaking, paper pulp, textiles, petrochemical industry, semiconductor electronic industry, and domains like sewage treatment are among the many chemical processes that use it.Wet wells, oil tanks, sump pumps, reservoirs, electroplating facilities, paper industries, wastewater, and drinking water

03

Uses of pH / ORP Transmitter

Adopt a big area PTFE liquid junction with easy maintenance and an advanced solid dielectric from across the world. Long-range reference diffusion route significantly increases electrode life in challenging conditions. Because the electrode is constructed from high-quality low-noise wire, the signal output may be produced for up to 40 meters without interference. It also has excellent precision, quick reaction times, and strong repeatability.

pH / ORP Transmitter Calibration

Enter the ORP calibration screen, the first ORP electrode intothe86mV standard solution, standing for a moment, to be shown after the stability, press the ENT,
then the ORP electrode into the 256mV standard solution, static Set a moment, after the display is stable, press the ENT display calibration is successful, ORP calibration process is over.

Technical Specification

Technical Specification

Product
 pH meter, pH controller
Model
WXP6300
Measuring range
PH(0-14) / ORP(-1000~+1000mV)
Measuring medium
Liquid
Input Resistance
≥1012Ω
Temp compensation
NTCS10K (Standard) & PT1000
Temperature Range
-10~130℃, NTC10K or PT1000
Communication
RS485, Modbus-RTU
Signal output
4-20mA, maximum loop 750Ω, 0.2%FS
Power supply
AC220V±10%
24VDC±10%
Relay output
250V, 3A
Calibration
4/7/10 ph
Relay output
2
Transmission signals
4-20 mA
Size
96*96mm

Sensors

234-5312-!m

Features

Easy operation.
Enclosure for field mounting and panel mounting.
Automatically Temperature Compensation.
Directly switchable to PH or ORP.
Large LCD display with background lighting.
PH or ORP sensors can be connected
Using the setup program: user-friendly.

Set buzzer, LCD backlight switch function.

Using isolated transmission output, less affected by interference.

Set high and low alarm and hysteresis functions.

Programming 4-20mA analog output
RS485 communication-MODBUS-RTU
Relay output.

The principleof pH/ORPsensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which ismade up of 2half-cells, of which one is called ameasuring cell whose potential is related to specific ionic activity; the other is a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument.The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value. WKP100 is a digital sensor with RS485 designed by our company for the aquiculture industry, which can be used to measure the change of pH/ORP value in an aqueous solution system within the range. The sensor with a standard RS485 MODBUS-RTU protocol interface, which can be connected with the host computer conducts remote communication Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations.

Applications

Heating and Cooling Reactors

Heating and cooling reactors are crucial components in various industrial processes, particularly in chemical, pharmaceutical, and food industries. These reactors are used for carrying out reactions under controlled temperature conditions.

Disinfecting and
Sterilizing

Disinfection and sterilization are critical processes across various industries, particularly in healthcare, pharmaceuticals, food processing, and biotechnology. These applications ensure the elimination of harmful microorganisms.

Waste Heat Recovery Boilers

Waste heat recovery boilers are essential components in industries where significant amounts of heat are generated during various processes but are typically wasted. These boilers capture this waste heat and convert it into useful energy, thereby improving.

Dyeing WasteWater

Treatment of highly coloured wastewater containing a variety of dyes in varying quantities is a major component of wastewater treatment in the textile and dye industry.The flow of dye into the interior of the fibre as well as the interaction between a dye .

Exhaust Gas Treatment

Exhaust gas treatment systems (EGTS), also referred to as SOX scrubbers, are an alternative to these solutions that clean the exhaust gas in order to reduce SOX emissions to a level that is equivalent to the acceptable fuel sulphur content.

Fertigation System

Fertigation is the process of injecting fertilisers into an irrigation system for the purpose of amending the soil, the water, and other water-soluble goods. Adding chemicals to an irrigation system is known as chemigation, which is connected to fertigation.

Accessories

Documents

Wellkonix global commitment to the Chemical Industry