ORP Sensor
WORP0506
Features
- Industrial wastewater engineering
- Process measurements, electroplating plants, paper industry, drinks industry
- Wastewater containing oil
- Suspensions, varnishes, media containing solid particles
- Two-chamber system for when electrode poisons are present
- Media containing fluorides (hydrofluoric acid) up to 1000 mg/l HF
Primary cell is another name for the WORP0506 pH sensor that is used to test ORP. A mechanism called the primary battery transforms chemical energy into electrical energy. Electromotive force (EMF) is the term used to describe this battery’s voltage. Two half-cells make up the electromotive force (EMF) in question.
01
ORP Measurement Basics For The Process Industry
The ability of a medium to oxidise or reduce another medium is measured by its “oxidaon-reducon potenal,” or ORP. When an oxidizer takes an electron from another molecule, it is said to be oxidising, and when a reducer gives an electron to another molecule, it is said to be reducing. A single mV value, which can be positive or negative, can be monitored by an ORP sensor to identify whether oxidation or reduction is taking place. The mV value is positive when a medium is oxidising. The mV reading will be negative when it is displaying reduction. Additionally, an ORP measurement known as “Redox” is frequently used. Reduction and oxidation are combined to form the word redox. Oxidation-reduction potential (ORP) measures the ability of a lake or river to cleanse itself or break down waste products, such as contaminants and dead plants and animals. When the ORP value is high, there is lots of oxygen present in the water. This means that bacteria that decompose dead tissue and contaminants can work more efficiently.

02
Application of ORP Meter
Microbiological technology, medicines, food and drink, sugar production, chlor-alkali, mining and smelting, papermaking, paper pulp, textiles, petrochemical industry, semiconductor electronic industry, and domains like sewage treatment are among the many chemical processes that use it.Wet wells, oil tanks, sump pumps, reservoirs, electroplating facilities, paper industries, wastewater, and drinking water

03
Uses of ORP Meter
Adopt a big area PTFE liquid junction with easy maintenance and an advanced solid dielectric from across the world. Long-range reference diffusion route significantly increases electrode life in challenging conditions. Because the electrode is constructed from high-quality low-noise wire, the signal output may be produced for up to 40 meters without interference. It also has excellent precision, quick reaction times, and strong repeatability.
ORP Calibration
Enter the ORP calibration screen, the first ORP electrode intothe86mV standard solution, standing for a moment, to be shown after the stability, press the ENT,
then the ORP electrode into the 256mV standard solution, static Set a moment, after the display is stable, press the ENT display calibration is successful, ORP calibration process is over.
Technical Specification
Product
Plastic ORP sensor
Model
WORP0506
Measurement range
-2000mV ~ 2000mV
sensor unit
245―270mV(15―30℃,256mV calibration fluid)
Temperature compensation
NTC10K/PT100/PT1000
Pressure range
≤0.6Mpa
sensor stability
± 4mV /24h
Temperature
0~80℃
Thread Connection
3/4NPT
Shell material
PPS
Slope
(PTS values) ≧95% (25℃)
Resistance
≦250 m Ω
Sensors

Features
Easy operation.
Enclosure for field mounting and panel mounting.
Automatically Temperature Compensation.
Directly switchable to PH or ORP.
Large LCD display with background lighting.
PH or ORP sensors can be connected
Using the setup program: user-friendly.
Set buzzer, LCD backlight switch function.
Using isolated transmission output, less affected by interference.
Set high and low alarm and hysteresis functions.
Programming 4-20mA analog output
RS485 communication-MODBUS-RTU
Relay output.
The principleof pH/ORPsensor measurement is electrochemical method and galvanic battery principle. The primary battery is a system whose function is to turn chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF) which ismade up of 2half-cells, of which one is called ameasuring cell whose potential is related to specific ionic activity; the other is a reference half-cell, commonly known as a reference sensor, which is generally interlinked with the measuring solution and is connected to the measuring instrument.The potential difference produced by the galvanic interaction inside the sensor is transmitted to the pH controller, and the corresponding algorithm is transmitted to display the pH value. WKP100 is a digital sensor with RS485 designed by our company for the aquiculture industry, which can be used to measure the change of pH/ORP value in an aqueous solution system within the range. The sensor with a standard RS485 MODBUS-RTU protocol interface, which can be connected with the host computer conducts remote communication Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations.
Applications
Heating and Cooling Reactors
Disinfecting and Sterilizing
ensure the elimination of harmful microorganisms.
Waste Heat Recovery Boilers
Dyeing WasteWater
Exhaust Gas Treatment
content.
Fertigation System
Accessories
Documents

Wellkonix global commitment to the Chemical Industry
Wellkonix is the world leader in automation solutions to the chemical industry. As a global player, we have strong local support in any region that you run your business
Solutions
automation
Project execution
Providing solutions of every kind, at all times in chemical industries
WellKonix engineers were all very affected person and cooperative during the early engineering and start-up phases. We labored as one team thru to the completion of this plant project